The PXIe-4162 PXI Source Measure Unit, part number 785680-01, features 12 SMU channels, a 100 pA current resolution, up to 100 kS/s test speed, and a voltage range
The PXIe-4162 PXI Source Measure Unit, with part number 785680-01, is a high-precision instrument featuring 12 SMU channels and a fine current resolution of 100 pA.
Capable of conducting tests at speeds of up to 100 kS/s, this unit is equipped with a SourceAdapt feature to optimize performance across various loads. The PXIe-4162 operates within a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA, providing flexibility for a wide array of testing requirements.
The device requires NI-DCPower driver software for operation, which can be developed in either LabVIEW or LabWindows/CVI environments, and configurations can be managed using the Measurement & Automation Explorer (MAX) tool.
Designed for efficiency, the PXIe-4162 is a single-slot module that measures 0.8 x 5.1 x 8.5 inches and weighs only 13.9 ounces. For maintaining accuracy and reliability, the unit offers calibration services, with NIST accredited options available, and it is recommended to be calibrated either annually or every two years.
Specification
Detail
Part Number
785680-01
Product Name
PXIe-4162 PXI Source Measure Unit
SMU Channels
12
Current Resolution
100 pA
Test Speed
Up to 100 kS/s
SourceAdapt Feature
Yes
Voltage Range
-24 V to 24 V
Current Range
-100 mA to 100 mA
Driver Software
NI-DCPower
App Development Environment
LabVIEW or LabWindows/CVI
Configuration Tool
Measurement & Automation Explorer (MAX)
Module Slot
Single-slot
Dimensions
0.8 x 5.1 x 8.5 in
Weight
13.9 oz
Calibration Availability
Yes, NIST accredited options available
Recommended Calibration Period
Annually or every two years
Question 1: What testing capabilities does the PXIe-4162 PXI Source Measure Unit with part number 785680-01 offer in terms of channel count, resolution, and voltage and current ranges? Answer 1: The PXIe-4162 PXI Source Measure Unit operates within a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA, and it is recommended to calibrate the device annually or every two years for optimal accuracy.
Question 2: What is the current resolution and the voltage range of the PXIe-4162 PXI Source Measure Unit, and how often is it recommended to calibrate the instrument for maintaining accuracy? Answer 2: The PXIe-4162 PXI Source Measure Unit operates within a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA, and it is recommended to calibrate the device annually or every two years.
Question 3: What is the voltage and current range of the PXIe-4162 PXI Source Measure Unit, and how often is it recommended to calibrate this device? Answer 3: The PXIe-4162 PXI Source Measure Unit is equipped with the SourceAdapt feature, which allows it to optimize performance across different loads, and for maintaining accuracy and reliability, it is recommended that the instrument be calibrated either annually or every two years.
Question 4: What features make the PXIe-4162 PXI Source Measure Unit capable of optimizing performance across different loads, and how often is it recommended to calibrate this instrument for accuracy? Answer 4: The PXIe-4162 PXI Source Measure Unit, part number 785680-01, offers testing capabilities with 12 SMU channels, a fine current resolution of 100 pA, and operates within a voltage range of -24 V to 24 V and a current range of -100 mA to 100 mA.
Question 5: What are the specific voltage and current ranges of the PXIe-4162 PXI Source Measure Unit, and how often is it recommended to calibrate the device for optimal accuracy? Answer 5: The PXIe-4162 PXI Source Measure Unit has a fine current resolution of 100 pA and operates within a voltage range of -24 V to 24 V; it is recommended to calibrate the instrument annually or every two years to maintain accuracy.