PXIe-4340

The National Instruments PXIe-4340 is a 24-bit, 4-channel displacement input module that supports AC LVDT, RVDT, resolvers, and synchros, with up to 25.6 kS/s sampling rate

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-4340 is a high-precision Displacement Input Module with part number 785068-01 designed to work with a variety of sensors including AC LVDT, AC RVDT, Resolver, and Synchro. It boasts a robust sampling rate of up to 25.6 kS/s per channel across its four concurrently sampled channels, ensuring accurate and synchronized data acquisition.

    The module is equipped with a 24-bit ADC resolution for high-resolution measurements and offers flexibility with independently selectable excitation frequency and voltage for each channel, allowing for a tailored setup for different sensor requirements. The built-in remote sensor system is designed to compensate for errors in excitation leads, which is particularly beneficial for long cable runs susceptible to resistance-induced inaccuracies.

    Furthermore, the PXIe-4340 includes a self-calibration feature that adjusts radiometric gain and offset to account for any analog drift on the motherboard, ensuring reliable and stable performance over time. The module’s ability to synchronize multiple channels on the same board—with identical excitation frequency and amplitude—makes it an ideal solution for complex measurement systems requiring high synchronization accuracy.

    Feature Description
    Part Number 785068-01
    Product Model PXIe-4340
    Manufacturer National Instruments
    Type Displacement Input Module
    Supported Sensors AC LVDT, AC RVDT, Resolver, Synchro
    Sampling Rate Up to 25.6 kS/s per channel
    Number of Channels 4 concurrently sampled channels
    ADC Resolution 24-bit
    Excitation Frequency Independently selectable per channel
    Excitation Voltage Independently selectable per channel
    Remote Sensor System Built-in, for error compensation in excitation leads
    Self-Calibration Feature Available, to adjust radiometric gain and offset
    Synchronization Supports multi-channel synchronization on the same board with the same excitation frequency and amplitude

    Question 1: What are the key features and capabilities of the National Instruments PXIe-4340 Displacement Input Module, including its compatibility with various sensors, channel sampling rate, and built-in calibration functions?
    Answer 1: The National Instruments PXIe-4340 is compatible with AC LVDT, AC RVDT, Resolver, and Synchro sensors, and its self-calibration feature contributes to maintaining accurate measurements by adjusting the radiometric gain and offset to compensate for any analog drift on the motherboard, ensuring reliable and stable performance over time.

    Question 2: What types of sensors are compatible with the National Instruments PXIe-4340 Displacement Input Module, and how does its remote sensor system enhance performance for long cable runs?
    Answer 2: The National Instruments PXIe-4340 Displacement Input Module is a high-precision device compatible with AC LVDT, AC RVDT, Resolver, and Synchro sensors, featuring a sampling rate of up to 25.6 kS/s per channel on four concurrently sampled channels, a 24-bit ADC resolution for high-resolution measurements, independently selectable excitation frequencies and voltages for each channel, a remote sensor system to correct excitation lead errors, and a self-calibration feature to

    Question 3: What types of sensors is the National Instruments PXi-4340, with its four concurrently sampled channels and high-resolution 24-bit ADC, compatible with, and how does its self-calibration feature contribute to maintaining accurate measurements?
    Answer 3: The National Instruments PXIe-4340 Displacement Input Module is suitable for high-precision measurements across different sensor types due to its robust 25.6 kS/s sampling rate per channel, 24-bit ADC resolution, independently selectable excitation frequency and voltage for each channel, built-in remote sensor system for error compensation, self-calibration feature, and the capability to synchronize multiple channels with identical excitation parameters, ensuring accurate and synchronized data acquisition.

    Question 4: What features of the National Instruments PXIe-4340 Displacement Input Module make it suitable for high-precision measurements across different sensor types?
    Answer 4: The National Instruments PXIe-4340 Displacement Input Module is compatible with AC LVDT, AC RVDT, Resolver, and Synchro sensors, and its remote sensor system enhances performance for long cable runs by compensating for errors due to resistance in the excitation leads, ensuring greater measurement accuracy.

    Question 5: What capabilities does the National Instruments PXIe-4340 offer in terms of excitation configuration for each of its four channels, and how does it ensure high-accuracy synchronization for complex measurement systems?
    Answer 5: The National Instruments PXIe-4340 offers the capability for independently selectable excitation frequency and voltage for each of its four channels, allowing for customized configurations to meet various sensor requirements, and it ensures high-accuracy synchronization for complex measurement systems through its ability to synchronize multiple channels on the same board with identical excitation frequency and amplitude.