Description
The National Instruments PXIe-5162 Oscilloscope/Digitizer, with part numbers 782622-01, 782622-05, and 782622-06, is designed to fit within a small-form factor, low-control PXI platform.
It features four input channels and offers a maximum sample rate that varies depending on the number of channels used: 5 GS/s for a single channel, 2.5 GS/s for two channels, and 1.25 GS/s for four channels, allowing for flexible data acquisition.
The device provides a bandwidth of 1.5 GHz on the 50 Ω path and 300 MHz on the 1 MΩ path, ensuring high fidelity in signal capturing.
Equipped with deep onboard memory, the PXIe-5162 is capable of handling large datasets, while boasting a data throughput greater than 600 MB/s, ensuring efficient data processing and transfer.
The oscilloscope/digitizer is compatible with PCI Express x4 Gen 1, allowing it to connect seamlessly to the PXI Express backplane, which enhances system integration and scalability.
For advanced applications requiring multiple synchronized channels, the NI-TClk API provides channel expansion capabilities with an impressive synchronization skew of just 100 ps between modules, simplifying the setup for complex configurations.
With its versatility, the National Instruments PXIe-5162 is an ideal instrument for a wide range of applications, particularly in the fields of time and frequency domain measurements.
Specification | Detail |
---|---|
Product Name | National Instruments PXIe-5162 Oscilloscope/Digitizer |
Part Numbers | 782622-01, 782622-05, 782622-06 |
Form Factor | Small-form factor, low-control PXI platform |
Input Channels | 4 channels |
Maximum Sample Rate | 5 GS/s (single channel), 2.5 GS/s (two channels), 1.25 GS/s (four channels) |
Bandwidth | 1.5 GHz (50 Ω path), 300 MHz (1 MΩ path) |
Onboard Memory | Deep onboard memory |
Data Throughput | Greater than 600 MB/s |
PCI Express Compatibility | x4 Gen 1, connects to PXI Express backplane |
Channel Expansion | NI-TClk API for multichannel synchronization with 100 ps of skew between modules |
Applications | Time and frequency domain measurements |
Question 1: What are the varying maximum sample rates of the National Instruments PXIe-5162 Oscilloscope/Digitizer for one, two, and four input channels, respectively?
Answer 1: The maximum sample rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when all four input channels are in use is 1.25 GS/s.
Question 2: What is the maximum sample rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when using all four input channels?
Answer 2: The National Instruments PXIe-5162 Oscilloscope/Digitizer offers maximum sample rates of 5 GS/s for one channel, 2.5 GS/s for two channels, and 1.25 GS/s for four channels, respectively.
Question 3: What is the maximum sampling rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when all four input channels are in use?
Answer 3: The National Instruments PXIe-5162 Oscilloscope/Digitizer offers a maximum sample rate of 5 GS/s when using one channel, 2.5 GS/s when using two channels, and 1.25 GS/s when all four channels are in use.
Question 4: What sample rates does the National Instruments PXIe-5162 Oscilloscope/Digitizer offer when using different numbers of its four input channels?
Answer 4: The maximum sampling rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when all four input channels are in use is 1.25 GS/s.
Question 5: What is the maximum sample rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when all four input channels are in use?
Answer 5: The maximum sample rate of the National Instruments PXIe-5162 Oscilloscope/Digitizer when using all four input channels is 1.25 GS/s.