The National Instruments PXIe-5603 RF Signal Downconverter Module, available in versions with and without a pre-amp, facilitates the conversion of RF frequency to a lower level for digitization, supports a maximum center frequency of up to 3
The National Instruments PXIe-5603 RF Signal Downconverter Module, with part numbers 781429-01 and 781429-02, is designed to convert RF frequencies to lower levels for efficient digitization, featuring a maximum center frequency capability of up to 3.6 GHz. Available in two versions, one without a pre-amp and another with a pre-amp (781429-02), this module ensures versatility for various applications.
It utilizes an SMA female connector and supports both AC and DC coupling, with a maximum DC input voltage of ±25 VDC and a maximum IF output level of +22 dBm. The resolution and temperature stability of the PXIe-5603 are guaranteed to be not less than those of the NI PXIe 5622, ensuring reliable performance.
The device requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power and can handle a LO IN maximum safe voltage of 25 VDC, with a LO OUT maximum safe voltage of 0 VDC. Weighing 32.0 oz, the PXIe-5603 is a robust component suitable for a range of signal processing tasks.
Feature
Specification
Part Number
781429-01, 781429-02
Manufacturer
National Instruments
Product
PXIe-5603 RF Signal Downconverter Module
Versions
Without pre-amp, With pre-amp (781429-02)
Function
Convert RF frequency to a lower level for digitization
Max Center Frequency
Up to 3.6 GHz
Connector Type
SMA female
Coupling Supported
AC and DC
Max DC Input Voltage
±25 VDC
Max IF Output Level
+22 dBm
Resolution and Temperature Stability
Not less than NI PXIe 5622
Power Requirements
1.7 A at +3.3 VDC, 1.8 A at +12 VDC
LO IN Max Safe Voltage
25 VDC
LO OUT Max Safe Voltage
0 VDC
Weight
32.0 oz
Question 1: What is the difference in functionality between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, specifically part numbers 781429-01 and 781429-02? Answer 1: The difference between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, part numbers 781429-01 and 781429-02, is that the 781429-02 version includes a pre-amp, which enhances its ability to amplify weak signals, whereas the 781429-01 version does not have this feature.
Question 2: What are the key features and specifications of the National Instruments PXIe-5603 RF Signal Downconverter Module, including its part numbers, frequency capability, and power requirements? Answer 2: The National Instruments PXIe-5603 RF Signal Downconverter Module requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power, and it ensures reliable performance with a resolution and temperature stability that are guaranteed to be not less than those of the NI PXIe 5622.
Question 3: What are the key features and specifications of the National Instruments PXIe-5603 RF Signal Downconverter Module, including its center frequency capability, available versions with and without a pre-amp, and power requirements? Answer 3: The National Instruments PXIe-5603 RF Signal Downconverter Module features a maximum center frequency capability of 3.6 GHz, is offered in two versions with part numbers 781429-01 without a pre-amp and 781429-02 with a pre-amp, utilizes an SMA female connector, supports AC and DC coupling, and requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power.
Question 4: What are the differences between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, specifically part numbers 781429-01 and 781429-02? Answer 4: The National Instruments PXIe-5603 RF Signal Downconverter Module, with part numbers 781429-01 and 781429-02, features a maximum center frequency capability of up to 3.6 GHz and comes in two versions, one with a pre-amp (781429-02) and one without. It supports AC and DC coupling, uses an SMA female connector, and can handle a maximum DC input voltage of ±25 VDC and a maximum IF output level of +
Question 5: What are the power requirements for the National Instruments PXIe-5603 RF Signal Downconverter Module, and how does it ensure reliable performance in terms of resolution and temperature stability compared to the NI PXIe 5622? Answer 5: The primary difference between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module is that part number 781429-02 includes a pre-amp for enhanced signal processing, while part number 781429-01 does not have this feature.