img

PXIe-5663

The National Instruments PXIe-5663 Vector Signal Analyzer, with a frequency range from 10 MHz to 6.6 GHz, incorporates components such as the PXIe-5601 RF Downconverter Module, PXIe-5622

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-5663 Vector Signal Analyzer is an advanced, high-frequency signal analysis solution with a broad frequency range of 10 MHz to 6.6 GHz. It encompasses essential components such as the PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator, which together offer a comprehensive suite for RF signal processing.

    Compatible with popular development environments, the PXIe-5663 requires NI-RFSA driver software and is compatible with LabVIEW and LabWindows/CVI, providing a versatile platform for a wide range of applications. It features multiple connectors including RF OUT, LO IN, CLK IN, REF IN/OUT, and OUT connectors, ensuring flexible connectivity options.

    The device is characterized by a 30-minute warm-up time and is designed to operate reliably within an operational temperature range of 0 °C to 55 °C. For maintaining its high precision, calibration services are available and recommended either annually or biennially, depending on usage.

    With its robust design and comprehensive features, the PXIe-5663 is a powerful tool for professionals requiring precise RF measurements and analysis in demanding environments.

    Specification Detail
    Product Family National Instruments PXIe-5663 Vector Signal Analyzer
    Part Numbers 780415-01, 780415-02, 780414-01, 780414-02, 780413-01, 780413-02
    Frequency Range 10 MHz to 6.6 GHz
    Components PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, PXIe-5652 RF Signal Generator
    Software Compatibility LabVIEW, LabWindows/CVI (NI-RFSA driver software required)
    Connectors RF OUT, LO IN, CLK IN, REF IN/OUT, OUT connectors
    Warm-Up Time 30 minutes
    Operational Temperature Range 0 °C to 55 °C
    Calibration Available, recommended annually or biennially

    Question 1: What components constitute the National Instruments PXIe-5663 Vector Signal Analyzer, and which software and environments are required for its operation?
    Answer 1: The National Instruments PXIe-5663 Vector Signal Analyzer supports high-frequency signal analysis for diverse applications by offering a broad frequency range of 10 MHz to 6.6 GHz and compatibility with software development environments such as LabVIEW and LabWindows/CVI, alongside essential components like the PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator, which together provide a versatile and comprehensive suite for RF signal

    Question 2: What components are included in the National Instruments PXIe-5663 Vector Signal Analyzer, and what are its compatible software and temperature specifications?
    Answer 2: The National Instruments PXIe-5663 Vector Signal Analyzer includes the PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator to ensure it offers a comprehensive suite for RF signal processing.

    Question 3: What range of applications can the National Instruments PXIe-5663 Vector Signal Analyzer be used for given its compatibility with LabVIEW and LabWindows/CVI and the inclusion of essential modules such as the PXIe-5601, PXIe-5622, and PXIe-5652?
    Answer 3: The National Instruments PXIe-5663 Vector Signal Analyzer includes the PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator as its core components; it is compatible with NI-RFSA driver software and can be used with LabVIEW and LabWindows/CVI development environments. The device operates within a temperature range of 0 °C to 55 °C.

    Question 4: What components are included in the National Instruments PXIe-5663 Vector Signal Analyzer to ensure it offers a comprehensive suite for RF signal processing?
    Answer 4: The National Instruments PXIe-5663 Vector Signal Analyzer can be used for a wide range of applications including, but not limited to, wireless communications, RF signal characterization, spectrum monitoring, electronic warfare, and radar system analysis, benefiting from its compatibility with LabVIEW and LabWindows/CVI and the integration of modules like the PXIe-5601 RF Downconverter, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator, which together provide a

    Question 5: Considering its frequency range and compatibility with software development environments, how does the National Instruments PXIe-5663 Vector Signal Analyzer support high-frequency signal analysis for diverse applications?
    Answer 5: The National Instruments PXIe-5663 Vector Signal Analyzer comprises the PXIe-5601 RF Downconverter Module, PXIe-5622 IF Digitizer, and PXIe-5652 RF Signal Generator, and it requires the NI-RFSA driver software to operate, being compatible with development environments such as LabVIEW and LabWindows/CVI.