img

PXIe-6361

The National Instruments PXIe-6361 is a 16-bit Multifunction I/O Module with 16 single-ended or 8 differential analog input channels, 2 output channels, 24 DIO lines, up to 2.86

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-6361 PXI Multifunction I/O Module, with the part number 781055-01, is a highly capable device offering 16-bit resolution for precise measurement and control. It features 16 single-ended or 8 differential analog input channels, along with two analog output channels, and a substantial number of 24 digital I/O lines for versatile connectivity options.

    This module is designed to handle a wide range of data acquisition tasks with a maximum input sampling rate ranging from 1.0 MS/s to 2.0 MS/s, and a maximum output sampling rate that varies from 2.0 MS/s to 2.86 MS/s, offering flexibility for various applications. There is no specified limit to the minimum channel sampling rate, allowing for a broad spectrum of measurement intervals.

    Equipped with four 32-bit, 100 MHz counters, the PXIe-6361 excels in applications requiring precise timing, such as PWM, encoder operations, frequency measurements, event counting, and triggering. The module incorporates NI-STC3 timing and synchronization technology, ensuring that measurements and control are well-coordinated. Connectivity is facilitated through a 68-pin female VHDCI connector, making the module compatible with a range of peripherals.

    With a PCI Express Bus bandwidth of up to 250 MB/s, data transfer is rapid and efficient. The PXIe-6361 is also compatible with various versions of Windows, including Windows 10/8/7/Vista/XP, ensuring easy integration into existing systems. Before use, a warm-up time of 15 minutes is recommended for optimum performance.

    < Question 1: What is the maximum analog input sampling rate and the range for the maximum analog output sampling rate of the National Instruments PXIe-6361 PXI Multifunction I/O Module with part number 781055-01?
    Answer 1: The recommended warm-up time for the National Instruments PXIe-6361 PXI Multifunction I/O Module before commencing optimum performance operation is 15 minutes.

    Question 2: What is the recommended warm-up time for the National Instruments PXIe-6361 PXI Multifunction I/O Module before commencing optimum performance operation?
    Answer 2: The maximum analog input sampling rate for the National Instruments PXIe-6361 PXI Multifunction I/O Module, part number 781055-01, is 2.0 MS/s, and it utilizes a 68-pin female VHDCI connector for connectivity.

    Question 3: What are the specifications and capabilities of the National Instruments PXIe-6361 PXI Multifunction I/O Module in terms of resolution, input and output channels, sampling rates, and compatibility with operating systems?
    Answer 3: The National Instruments PXIe-6361 PXI Multifunction I/O Module, part number 781055-01, is a feature-rich device that offers 16-bit resolution for precise measurements, has 16 single-ended or 8 differential analog input channels and two analog output channels, and provides 24 digital I/O lines for versatile connectivity. It supports a maximum input sampling rate of 1.0 MS/s to 2.0 MS/s and an output sampling rate of 2

    Question 4: What is the maximum analog input sampling rate for the National Instruments PXIe-6361 PXI Multifunction I/O Module, part number 781055-01, and what type of connector does it utilize for connectivity?
    Answer 4: The National Instruments PXIe-6361 PXI Multifunction I/O Module offers 16-bit resolution, has 16 single-ended or 8 differential analog input channels, two analog output channels, and 24 digital I/O lines, with a maximum input sampling rate of 1.0 MS/s to 2.0 MS/s, and a maximum output sampling rate between 2.0 MS/s to 2.86 MS/s, and it is compatible with Windows 10,

    Question 5: What are the characteristics and capabilities of the National Instruments PXIe-6361 PXI Multifunction I/O Module with part number 781055-01, including its resolution, input and output channels, digital I/O lines, sampling rates, counter specifications, and system compatibility?
    Answer 5: The maximum analog input sampling rate of the National Instruments PXIe-6361 PXI Multifunction I/O Module with part number 781055-01 is 2.0 MS/s, and the range for the maximum analog output sampling rate varies from 2.0 MS/s to 2.86 MS/s.

    Feature Specification
    Product Name National Instruments PXIe-6361 PXI Multifunction I/O Module
    Part Number 781055-01
    Resolution 16-bit
    Analog Input Channels 16 single-ended or 8 differential
    Analog Output Channels 2
    Digital I/O Lines 24
    Maximum Input Sampling Rate 1.0 MS/s to 2.0 MS/s
    Maximum Output Sampling Rate 2.0 MS/s to 2.86 MS/s
    Minimum Channel Sampling Rate No limit
    Counter/Timers Four 32-bit, 100 MHz counters
    Timing and Synchronization Technology NI-STC3
    Connector Type 68-pin female VHDCI
    PCI Express Bus Bandwidth Up to 250 MB/s
    Operating System Compatibility Windows 10/8/7/Vista/XP
    Warm-Up Time 15 minutes