PXIe-8430-8

The National Instruments PXIe-8430/8 Serial Interface Module, with part number 781472-01, is an 8-port RS232 connection module featuring SCSI 68-pin to DB-9 male connectors, requiring up to 250

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-8430/8 Serial Interface Module, with Part Number 781472-01, is equipped with 8 RS232 serial ports featuring SCSI 68-pin to DB-9 male connectors, ensuring versatile connectivity options.

    This module requires a power input of 220 mA typical and 250 mA maximum at +12 VDC, and 200 mA typical and 750 mA maximum at +3.3 VDC, making it an energy-efficient addition to any setup. Weighing 143 grams and measuring 3.94 x 6.37 inches in size, it is compact and lightweight, allowing for easy integration into a range of systems.

    Designed to perform reliably in diverse environments, it operates within a temperature range of 0 to 55 °C and can be stored in conditions ranging from -40 to 71 °C. Humidity is also well-tolerated, with operating conditions from 10 to 90% RH and storage conditions from 5 to 95% RH, both non-condensing.

    The module’s robust build is evidenced by its capacity to withstand operating vibrations of 0.3 grms across a frequency range of 5 to 500 Hz, ensuring it can handle the rigors of active use without compromising performance.

    Question 1: What is the power requirement for the National Instruments PXIe-8430/8 Serial Interface Module, with a Part Number of 781472-01, and what are its physical dimensions and operating temperature range?
    Answer 1: The storage temperature range for the National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01 is from -40 to 71 °C.

    Question 2: What are the environmental operating and storage temperature ranges for the National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01?
    Answer 2: The National Instruments PXIe-8430/8 Serial Interface Module operates within a temperature range of 0 to 55 °C and can be stored in conditions ranging from -40 to 71 °C, and it manages humidity tolerances with operating conditions from 10 to 90% RH and storage conditions from 5 to 95% RH, both non-condensing.

    Question 3: What are the operating and storage temperature ranges of the National Instruments PXIe-8430/8 Serial Interface Module, and how does it manage humidity tolerances?
    Answer 3: The National Instruments PXIe-8430/8 Serial Interface Module, Part Number 781472-01, requires a power input of 220 mA typical and 250 mA maximum at +12 VDC, and 200 mA typical and 750 mA maximum at +3.3 VDC; it measures 3.94 x 6.37 inches in size and operates within a temperature range of 0 to 55 °C.

    Question 4: What are the power requirements and physical dimensions of the National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01?
    Answer 4: The National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01 operates within a temperature range of 0 to 55 °C and can be stored in conditions ranging from -40 to 71 °C.

    Question 5: What is the storage temperature range for the National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01?
    Answer 5: The National Instruments PXIe-8430/8 Serial Interface Module with Part Number 781472-01 requires a power input of 220 mA typical and 250 mA maximum at +12 VDC, and 200 mA typical and 750 mA maximum at +3.3 VDC, and has physical dimensions of 3.94 x 6.37 inches, weighing 143 grams.

    Specification Detail
    Product Name National Instruments PXIe-8430/8 Serial Interface Module
    Part Number 781472-01
    Ports 8
    Connector Type SCSI 68-pin to DB-9 male connectors
    Connection Standard RS232
    Power Requirement (at +12 VDC) 220 mA typical, 250 mA maximum
    Power Requirement (at +3.3 VDC) 200 mA typical, 750 mA maximum
    Weight 143 g
    Dimensions 3.94 x 6.37 in.
    Operating Temperature Range 0 to 55 °C
    Storage Temperature Range -40 to 71 °C
    Operating Humidity Range 10 to 90% RH (non-condensing)
    Storage Humidity Range 5 to 95% RH (non-condensing)
    Operating Vibration (Random) 0.3 grms (5 to 500 Hz)
    Non-Operating Vibration (Random)