REM-11178

The National Instruments REM-11178 is a 32-channel Digital Module for Remote I/O, compatible with 24V, featuring one-wire spring terminal connections, overload and short circuit protection, EtherCAT communication, and requires an external fuse for polarity

In Stock | Ships Today

img

    Description

    The National Instruments REM-11178, with part number 784746-01, is a robust Digital Module for Remote I/O designed to facilitate machine control and simple measurements through its 32 output channels. Operating at a maximum voltage of 24V, this module ensures secure connections using a one-wire spring terminal. It is capable of driving up to 500 mA of current per channel, with a total module capacity of 8 A, while safeguarding against electrical mishaps with its overload and short circuit protection.

    Communication with other systems is streamlined via the EtherCAT protocol, and the module requires a 24 VDC power supply. To prevent potential damage from reversing polarity, it is mandatory to connect an external fuse to the supply. Moreover, the REM-11178 is EMC compliant, ensuring it meets the standards for electromagnetic compatibility, making it a reliable choice for various industrial environments.

    Specification Detail
    Manufacturer National Instruments
    Part Number REM-11178
    National Instruments Part Number 784746-01
    Type Digital Module for Remote I/O
    Output Channels 32
    Maximum Voltage 24V
    Connection Type One-wire spring terminal
    Maximum Current per Channel 500 mA
    Maximum Current per Module 8 A
    Protection Overload and short circuit protection
    Communication Protocol EtherCAT
    Supply Voltage 24 VDC
    External Fuse Requirement Yes (for protection from reversing polarity)
    EMC Compatibility Compliant

    Question 1: What precautions are recommended when connecting the power supply to the National Instruments REM-11178 to safeguard against reverse polarity damage?
    Answer 1: When connecting the power supply to the National Instruments REM-11178, it is recommended to connect an external fuse to the supply in order to safeguard against reverse polarity damage.

    Question 2: What is the current capacity per channel and the total module capacity for the National Instruments REM-11178 Digital Module for Remote I/O?
    Answer 2: Each output channel on the National Instruments REM-11178 Digital Module for Remote I/O can drive up to 500 mA of current, and the module includes overload and short circuit protection features to safeguard against electrical issues.

    Question 3: What is the maximum voltage and current per channel that the National Instruments REM-11178 Digital Module can handle, and what are its safety features?
    Answer 3: The current capacity per channel for the National Instruments REM-11178 Digital Module for Remote I/O is 500 mA, with a total module capacity of 8 A.

    Question 4: What is the current driving capacity of each output channel on the National Instruments REM-11178 Digital Module for Remote I/O, and what protection features does it include to safeguard against electrical issues?
    Answer 4: The National Instruments REM-11178 Digital Module for Remote I/O, part number 784746-01, operates at a maximum voltage of 24V and includes protection features such as overload and short circuit protection, while also requiring an external fuse to guard against reverse polarity damage.

    Question 5: What are the voltage requirements and protection features of the National Instruments REM-11178 Digital Module for Remote I/O, part number 784746-01?
    Answer 5: The National Instruments REM-11178 Digital Module can handle a maximum voltage of 24V and a current of up to 500 mA per channel, with safety features that include overload and short circuit protection.