The SCB-100A, also known as part number 785024-01, is a shielded I/O connector block by National Instruments, featuring 100 screw terminals, a magnetic removable lid, compatibility with various digital I/O and counter/t
The SCB-100A, also known as part number 785024-01, is a Shielded I/O Connector Block designed by National Instruments. This connector block features a magnetic removable lid for easy access and includes 100 screw terminals to facilitate simple and reliable I/O connections.
It is compatible with a variety of National Instruments modules, such as the PCI-DIO-96, NI-6513, NI-6514, NI-6511, NI-6512, NI-6508, NI-6509, NI-6515, NI-6528, NI-6529, and NI-6624 Counter/Timer devices. To connect with these modules, the SCB-100A utilizes the SH100-100-F Cable (Part Number: 185095-0x).
For mounting purposes, the SCB-100A can be fixed using the NI-9913 DIN rail mounting kit (Part Number: 781740-01). This versatile connector block is designed to manage a maximum current of 0.5 A at terminals 1-48 and 51-98, and 1 A at terminals 49-50 and 99-100, with a maximum voltage capacity of 30 V RMS, 42 V peak, or 60 V DC.
At its core, the SCB-100A is equipped with a single 100-pin male 0.050 series shielded D-type connector. It operates using the NIDAQmx driver software, which is compatible with various application development environments, ensuring versatile and efficient use in a wide range of applications.
0.5 A at terminals 1-48, 51-98; 1 A at terminals 49-50, 99-100
Maximum Voltage
30 V RMS, 42 V peak, 60 V DC
Connector Type
One 100-pin male 0.050 series shielded D-type connector
Driver Software
NIDAQmx
Question 1: What type of cable is used to connect the SCB-100A, identified by part number 785024-01, to various National Instruments modules, and what is the part number for this cable? Answer 1: The SCB-100A Shielded I/O Connector Block can manage a maximum current of 0.5 A at terminals 1-48 and 51-98, and 1 A at terminals 49-50 and 99-100, with a maximum voltage capacity of 30 V RMS, 42 V peak, or 60 V DC, and it utilizes the SH100-100-F Cable (Part Number: 185095-0x) to connect to compatible National Instruments
Question 2: What is the maximum current and voltage capacity of the SCB-100A Shielded I/O Connector Block, and which cable is used to connect it to compatible National Instruments modules? Answer 2: The purpose of the magnetic removable lid on the SCB-100A Shielded I/O Connector Block designed by National Instruments is to allow for easy access to the connector block’s screw terminals, facilitating simple and reliable I/O connections.
Question 3: What is the maximum current handling capacity for terminals 1-48 and 51-98 vs. terminals 49-50 and 99-100 on the SCB-100A Shielded I/O Connector Block designed by National Instruments? Answer 3: The SCB-100A can manage a maximum current of 0.5 A at terminals 1-48 and 51-98 and 1 A at terminals 49-50 and 99-100, with a maximum voltage capacity of 30 V RMS, 42 V peak, or 60 V DC, and it utilizes the SH100-100-F Cable (Part Number: 185095-0x) to connect to compatible National Instruments modules.
Question 4: What is the purpose of the magnetic removable lid on the SCB-100A Shielded I/O Connector Block designed by National Instruments? Answer 4: The maximum current handling capacity for terminals 1-48 and 51-98 on the SCB-100A Shielded I/O Connector Block is 0.5 A, while terminals 49-50 and 99-100 can handle up to 1 A.
Question 5: What is the maximum current and voltage handling capacity of the SCB-100A, and what cable is used to connect the SCB-100A to compatible National Instruments modules? Answer 5: The SCB-100A, identified by part number 785024-01, uses the SH100-100-F Cable to connect to various National Instruments modules, and the part number for this cable is 185095-0x.