The National Instruments SCB-68 is a shielded I/O connector block with part numbers 776844-01 and 782914-01, compatible with several DAQ series, featuring a cold-junction compensation sensor, configurable via MAX, and

In Stock | Ships Today

img

    Description

    The National Instruments SCB-68 is a versatile Shielded I/O Connector Block with part numbers 776844-01 and 782914-01, designed to provide noise-rejecting signal connections for a wide range of data acquisition devices.

    It is compatible with 68-pin X Series, M Series, E Series, B Series, S Series, and R Series DAQ devices, making it a highly adaptable solution for various measurement and automation applications. The SCB-68 is equipped with an onboard cold-junction compensation sensor and features such as general-purpose breadboard areas, screw terminals, and sockets for interchanging components, which facilitate customized signal conditioning and rapid prototyping.

    The device boasts an impressive temperature sensor accuracy of ±1.0 °C across a range of 0 to 110 °C and provides a temperature sensor output of 10 mV/°C. Users can configure the SCB-68 using the Measurement & Automation Explorer (MAX) software tool, simplifying setup and calibration processes.

    Regarding power, the SCB-68 has a typical requirement of 1 mA at +5 VDC and can draw a maximum of 800 mA from the host computer without additional signal conditioning installed. It connects via a 68-pin male SCSI I/O connector and accepts wire gauges ranging from 14-30 AWG.

    This Shielded Connector Block is not only functional but also compact, weighing 13 oz and measuring 7.7 x 6.0 x 1.8 inches. It is designed to operate within a temperature range of 0 to 70 °C, ensuring reliable performance in various environments.

    Question 1: What are the features of the National Instruments SCB-68 that support customized signal conditioning and rapid prototyping in data acquisition systems?
    Answer 1: The National Instruments SCB-68 Shielded I/O Connector Block measures 7.7 x 6.0 x 1.8 inches and weighs 13 ounces.

    Question 2: What types of data acquisition devices is the National Instruments SCB-68 Shielded I/O Connector Block compatible with, and what are the features that facilitate customized signal conditioning and rapid prototyping?
    Answer 2: The National Instruments SCB-68, identified by part numbers 776844-01 and 782914-01, is highly adaptable and convenient for use with multiple series of DAQ devices due to its compatibility with 68-pin X Series, M Series, E Series, B Series, S Series, and R Series DAQ devices, and it assists in custom signal conditioning and rapid prototyping with features such as an onboard cold-junction compensation sensor, general-purpose breadboard areas, screw terminals,

    Question 3: What features of the National Instruments SCB-68, identified by part numbers 776844-01 and 782914-01, contribute to its adaptability and convenience for use with multiple series of DAQ devices, and how do they assist in custom signal conditioning and rapid prototyping?
    Answer 3: The National Instruments SCB-68 Shielded I/O Connector Block is compatible with 68-pin X Series, M Series, E Series, B Series, S Series, and R Series DAQ devices, and it facilitates customized signal conditioning and rapid prototyping through features such as an onboard cold-junction compensation sensor, general-purpose breadboard areas, screw terminals, and sockets for interchanging components.

    Question 4: What are the dimensions and weight of the National Instruments SCB-68 Shielded I/O Connector Block?
    Answer 4: The National Instruments SCB-68 Shielded I/O Connector Block typically requires 1 mA at +5 VDC and can draw a maximum of 800 mA from the host computer; it weighs 13 ounces and measures 7.7 x 6.0 x 1.8 inches.

    Question 5: What power requirements does the National Instruments SCB-68 Shielded I/O Connector Block have when connected to a host computer, and what are its weight and dimensions?
    Answer 5: The National Instruments SCB-68 supports customized signal conditioning and rapid prototyping in data acquisition systems through its general-purpose breadboard areas, screw terminals, and sockets for interchanging components, coupled with an onboard cold-junction compensation sensor for enhanced measurement accuracy.

    Specification Detail
    Part Numbers 776844-01, 782914-01
    Manufacturer National Instruments
    Type Shielded I/O Connector Block
    Compatibility 68-pin X Series, M Series, E Series, B Series, S Series, R Series DAQ devices
    Onboard Features Cold-junction compensation sensor, general-purpose breadboard areas, screw terminals, sockets for interchanging components
    Temperature Sensor Accuracy ±1.0 °C over a 0 to 110 °C range
    Temperature Sensor Output 10 mV/°C
    Configuration Tool Measurement & Automation Explorer (MAX)
    Power Requirements Typical: 1 mA at +5 VDC, Maximum: 800 mA from host computer
    Connectors 1 68-pin male SCSI I/O connector
    Wire Gauge 14-30 AWG
    Weight 13 oz
    Dimensions 7.7 x 6.0 x 1.8 inches
    Operating Temperature Range 0 to 70 °C