img

SCC-68

The National Instruments SCC-68 Terminal Block (Part Number 779475-01) is a RoHS-compliant device with four SCC slots for various modules, 68 screw terminals for I/O signal connection, stacking capabilities, and a built-in temperature

In Stock | Ships Today

img

    Description

    The National Instruments SCC-68 Terminal Block, with a part number of 779475-01, is an essential component designed to accommodate four SCC slots for various signal conditioning modules. These modules include but are not limited to a lowpass filter, strain gauge, RTD input, frequency input, thermocouple, current input, voltage attenuator, load cell input, accelerometer, SPDT relay, and isolated voltage input.

    This terminal block is RoHS compliant, ensuring adherence to environmental standards. The SCC-68 boasts 68 screw terminals for I/O signal connection, alongside bus terminals for providing external power and grounding, all within a robust construction.

    For enhanced compatibility, it supports various cables including the RC68-68, SHC68-68-EPM, or SHC68-68. A unique feature of the SCC-68 is its stacking capability, with dedicated grooves for secure stacking of SCC-68 Connector Blocks, although stacking is not recommended when back rubber feet are attached.

    Integrated within the terminal block are temperature sensor terminals at positions 70 (CJC+) and 71, which are crucial for cold-junction compensation in thermocouple measurements. The power requirement for this device is minimal, requiring only 1 mA at 5 VDC when no signal conditioning is installed. Additionally, the SCC-68 is designed to withstand a maximum working voltage of 11 VDC (CAT I) from any channel to earth.

    The terminal block is lightweight, tipping the scales at just 6 oz, and has compact physical dimensions of 9.63 x 7.00 x 2.09 inches, making it suitable for a variety of desktop measurement system configurations.

    Specification Detail
    Product Name National Instruments SCC-68 Terminal Block
    Part Number 779475-01
    SCC Slots 4
    Compatible Modules Lowpass filter, strain gauge, RTD input, frequency input, thermocouple, current input, voltage attenuator, load cell input, accelerometer, SPDT relay, isolated voltage input, and more
    Compliance RoHS
    Connection Type 68 screw terminals for I/O signal connection, bus terminals for external power and grounding
    Cable Compatibility RC68-68, SHC68-68-EPM, or SHC68-68
    Stacking Capability Yes, with grooves for stacking SCC-68 Connector Blocks (not stackable with back rubber feet)
    Temperature Sensor Terminals 70 (CJC+), 71
    Power Requirements 1 mA at 5 VDC (without signal conditioning installed)
    Channel-to-Earth Voltage 11 VDC (CAT I)
    Weight 6 oz
    Dimensions 9.63 x 7.00 x 2.09 in

    Question 1: What are the two temperature sensor terminal positions integrated within the National Instruments SCC-68 Terminal Block and what is their function?
    Answer 1: The two temperature sensor terminal positions integrated within the National Instruments SCC-68 Terminal Block are at positions 70 (CJC+) and 71, and their function is to provide cold-junction compensation for accurate thermocouple measurements.

    Question 2: What are the features and specifications of the National Instruments SCC-68 Terminal Block, particularly in terms of its compatibility, power requirements, and design attributes for thermocouple measurements?
    Answer 2: The National Instruments SCC-68 Terminal Block can accommodate a variety of signal conditioning modules, including a lowpass filter, strain gauge, RTD input, frequency input, thermocouple, current input, voltage attenuator, load cell input, accelerometer, SPDT relay, and isolated voltage input.

    Question 3: Considering the diverse range of signal conditioning modules that can be accommodated by the National Instruments SCC-68 Terminal Block, what specific types of modules can be used with it?
    Answer 3: The temperature sensor terminals at positions 70 (CJC+) and 71 on the National Instruments SCC-68 Terminal Block are designed for cold-junction compensation in thermocouple measurements; key features of the SCC-68 include compatibility with RC68-68, SHC68-68-EPM, or SHC68-68 cables, a minimal power requirement of 1 mA at 5 VDC when no signal conditioning is installed, the ability to withstand a maximum working voltage of 11 V

    Question 4: What are the specific features and capabilities of the National Instruments SCC-68 Terminal Block, including its compatibility with signal conditioning modules and cables, and how do its size and power requirements contribute to its suitability for desktop measurement system configurations?
    Answer 4: The National Instruments SCC-68 Terminal Block accommodates four SCC slots for signal conditioning modules, is RoHS compliant with 68 screw terminals, and features bus terminals for power and grounding within a robust construction. It is compatible with RC68-68, SHC68-68-EPM, or SHC68-68 cables, offers stacking capabilities, and includes temperature sensor terminals at positions 70 and 71 for cold-junction compensation in thermocouple measurements. The SCC-68 requires a minimal

    Question 5: What is the purpose of the temperature sensor terminals located at positions 70 (CJC+) and 71 on the National Instruments SCC-68 Terminal Block, and what are its key features regarding compatibility, power requirements, and physical dimensions?
    Answer 5: The National Instruments SCC-68 Terminal Block, part number 779475-01, is designed to accommodate four SCC slots for signal conditioning modules such as lowpass filters, strain gauges, RTD and frequency inputs, thermocouples, current and voltage inputs, load cells, accelerometers, SPDT relays, and isolated voltage inputs. It is RoHS compliant, featuring 68 screw terminals for I/O connections and bus terminals for external power and grounding within a robust frame. It supports RC