Description
The National Instruments SCC-AI06 Isolated Analog Input Module, with a part number 777459-25, is designed for high-precision applications with a gain of 100 and a bandwidth of 10 kHz. It can handle an input range of ±100 mV, and provides an output range of ±10 V, ensuring accurate signal processing in a variety of industrial settings.
This module offers channel-to-ground and module-to-module isolation, but it should be noted that there is no isolation between the two channels. It is equipped with one 20-pin right-angle male connector and one removable 4-pin screw terminal for versatile connectivity options.
The SCC-AI06 has an analog power requirement of up to 410 mW, while the digital power can go up to a maximum of 650 mW. Its lightweight design weighs in at just 1.0 oz, and it is compatible with wire gauges ranging from 24 to 12 AWG.
Optimal performance is maintained within an operating temperature range of 0 to 50 °C and a storage temperature range of –20 to 70 °C. The module also operates reliably in a relative humidity range of 10 to 90% (non-condensing), ensuring durability and stability across diverse environmental conditions.
Specification | Details |
---|---|
Part Number | 777459-25 |
Product | National Instruments SCC-AI06 Isolated Analog Input Module |
Gain | 100 |
Bandwidth | 10 kHz |
Input Range | ±100 mV |
Output Range | ±10 V |
Isolation | Channel-to-ground and module-to-module only (No isolation between the two channels) |
Connectors | One 20-pin right-angle male connector, One removable 4-pin screw terminal |
Power Requirement (Analog) | Up to 410 mW |
Power Requirement (Digital) | 650 mW maximum |
Weight | 1.0 oz |
Wire Gauge | 24 to 12 AWG |
Operating Temperature Range | 0 to 50 °C |
Storage Temperature Range | –20 to 70 °C |
Relative Humidity Range | 10 to 90% (non-condensing) |
Question 1: What are the isolation features and connectivity options provided by the National Instruments SCC-AI06 Isolated Analog Input Module?
Answer 1: The optimal operating temperature range for the National Instruments SCC-AI06 Isolated Analog Input Module is 0 to 50 °C, while the storage temperature range is -20 to 70 °C.
Question 2: What are the temperature ranges for optimal performance and storage of the National Instruments SCC-AI06 Isolated Analog Input Module?
Answer 2: The National Instruments SCC-AI06 Isolated Analog Input Module requires up to 410 mW of analog power and a maximum of 650 mW of digital power for operation, and it performs optimally within an operating temperature range of 0 to 50 °C and a storage temperature range of -20 to 70 °C.
Question 3: What is the input range and output range of the National Instruments SCC-AI06 Isolated Analog Input Module with part number 777459-25, and what are its power requirements for both analog and digital functionality?
Answer 3: The National Instruments SCC-AI06 Isolated Analog Input Module, part number 777459-25, has an input range of ±100 mV and an output range of ±10 V. Its power requirements are up to 410 mW for analog functionality and a maximum of 650 mW for digital operations.
Question 4: What are the specific isolation features and connectivity options provided by the National Instruments SCC-AI06 Isolated Analog Input Module?
Answer 4: The National Instruments SCC-AI06 Isolated Analog Input Module offers channel-to-ground and module-to-module isolation, and comes equipped with one 20-pin right-angle male connector and one removable 4-pin screw terminal for connectivity, but it does not provide isolation between its two channels.
Question 5: What are the power requirements and temperature ranges for optimal performance of the National Instruments SCC-AI06 Isolated Analog Input Module?
Answer 5: The National Instruments SCC-AI06 Isolated Analog Input Module offers channel-to-ground and module-to-module isolation, but does not provide isolation between its two channels, and it features one 20-pin right-angle male connector along with one removable 4-pin screw terminal for versatile connectivity options.