SCC-AO10

The National Instruments SCC-AO10 (Part Number: 777459-50) is an isolated analog output module that offers up to ± 10 volts output range, compatibility with E/M Series DAQ devices, and features such as 60 V

In Stock | Ships Today

img

    Description

    The National Instruments SCC-AO10 Isolated Analog Output Module, with a part number of 777459-50, is designed to deliver an output voltage range of ± 10 volts, which can be extended to ± 20 volts by connecting two modules. Compatible with E/M Series DAQ devices, this module ensures isolation up to 60 VDC common mode and features a gain nonlinearity of only 0.5% over the full-scale output range.

    Its output noise is kept minimal with a typical value of 2.5 mV and a maximum of 4 mV, while it can drive a current of ± 30 mA. For safety, it includes short circuit protection capable of handling up to 37 mA indefinitely. To achieve accurate measurements, a calibration warm-up time of 30 minutes is recommended before use.

    Specification Detail
    Part Number 777459-50
    Product Type Isolated Analog Output Module
    Manufacturer National Instruments
    Output Voltage Range ± 10 volts (extendable up to ± 20 volts with two modules connected)
    Compatible Devices E/M Series DAQ device
    Isolation Up to 60 VDC common mode
    Gain Nonlinearity (Full-Scale Output Range) 0.5 %
    Output Noise (RMS) Typical: 2.5 mV, Maximum: 4 mV
    Current Drive ± 30 mA
    Short Circuit Protection Yes, up to 37 mA for an unlimited duration
    Calibration Warm-Up Time 30 minutes

    Question 1: What is the compatible device for the National Instruments SCC-AO10 Isolated Analog Output Module, and what is its recommended calibration warm-up time before use?
    Answer 1: The typical output noise value for the National Instruments SCC-AO10 Isolated Analog Output Module is 2.5 mV, and it can drive a current of ±30 mA.

    Question 2: What is the recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module before commencing accurate measurements?
    Answer 2: The National Instruments SCC-AO10 Isolated Analog Output Module can withstand a maximum common mode isolation voltage of 60 VDC, and its typical output noise value is 2.5 mV.

    Question 3: What is the maximum common mode isolation voltage that the National Instruments SCC-AO10 Isolated Analog Output Module can withstand, and what is its typical output noise value?
    Answer 3: The National Instruments SCC-AO10 Isolated Analog Output Module is compatible with E/M Series DAQ devices, and its recommended calibration warm-up time before use is 30 minutes.

    Question 4: What is the typical output noise value for the National Instruments SCC-AO10 Isolated Analog Output Module, and what current can it drive?
    Answer 4: The recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module before commencing accurate measurements is 30 minutes.

    Question 5: What is the recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module to ensure accurate measurements?
    Answer 5: The recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module to ensure accurate measurements is 30 minutes.