The National Instruments SCC-AO10 (Part Number: 777459-50) is an isolated analog output module that offers up to ± 10 volts output range, compatibility with E/M Series DAQ devices, and features such as 60 V


Phone: 1-800-915-6216

Email: sales@apexwaves.com

Description

The National Instruments SCC-AO10 Isolated Analog Output Module, with a part number of 777459-50, is designed to deliver an output voltage range of ± 10 volts, which can be extended to ± 20 volts by connecting two modules. Compatible with E/M Series DAQ devices, this module ensures isolation up to 60 VDC common mode and features a gain nonlinearity of only 0.5% over the full-scale output range.

Its output noise is kept minimal with a typical value of 2.5 mV and a maximum of 4 mV, while it can drive a current of ± 30 mA. For safety, it includes short circuit protection capable of handling up to 37 mA indefinitely. To achieve accurate measurements, a calibration warm-up time of 30 minutes is recommended before use.

Specification Detail
Part Number 777459-50
Product Type Isolated Analog Output Module
Manufacturer National Instruments
Output Voltage Range ± 10 volts (extendable up to ± 20 volts with two modules connected)
Compatible Devices E/M Series DAQ device
Isolation Up to 60 VDC common mode
Gain Nonlinearity (Full-Scale Output Range) 0.5 %
Output Noise (RMS) Typical: 2.5 mV, Maximum: 4 mV
Current Drive ± 30 mA
Short Circuit Protection Yes, up to 37 mA for an unlimited duration
Calibration Warm-Up Time 30 minutes

Q1: What is the compatible device for the National Instruments SCC-AO10 Isolated Analog Output Module, and what is its recommended calibration warm-up time before use?
A1: The typical output noise value for the National Instruments SCC-AO10 Isolated Analog Output Module is 2.5 mV, and it can drive a current of ±30 mA.

Q2: What is the recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module before commencing accurate measurements?
A2: The National Instruments SCC-AO10 Isolated Analog Output Module can withstand a maximum common mode isolation voltage of 60 VDC, and its typical output noise value is 2.5 mV.

Q3: What is the maximum common mode isolation voltage that the National Instruments SCC-AO10 Isolated Analog Output Module can withstand, and what is its typical output noise value?
A3: The National Instruments SCC-AO10 Isolated Analog Output Module is compatible with E/M Series DAQ devices, and its recommended calibration warm-up time before use is 30 minutes.

Q4: What is the typical output noise value for the National Instruments SCC-AO10 Isolated Analog Output Module, and what current can it drive?
A4: The recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module before commencing accurate measurements is 30 minutes.

Q5: What is the recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module to ensure accurate measurements?
A5: The recommended calibration warm-up time for the National Instruments SCC-AO10 Isolated Analog Output Module to ensure accurate measurements is 30 minutes.