SCXI-1104

The National Instruments SCXI-1104 Voltage Input Module (Part Number: 776572-04) is designed for signal conditioning of medium-voltage signals, featuring a three-pole lowpass filter with a 2 Hz cutoff frequency and is compatible

Product Description

The National Instruments SCXI-1104 Voltage Input Module, with part number 776572-04, is designed to condition medium-voltage signals with its capacity to handle 30 VACrms, ±42 VACpeak, and ±60 VDC voltage inputs. It features a three-pole lowpass filter with a 2 Hz cutoff frequency to mitigate noise, and it incorporates an SCXIbus interface to link the back signal connector to the SCXIbus for communication.

Moreover, the SCXI-1104 supports indirect scanning through a dedicated switch on the module, enhancing its versatility. For successful integration, it requires connectivity devices such as the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300. The module is compatible with various software platforms, including VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW, and requires NI-DAQ drivers for either Macintosh or PC Compatibles.

Physically, the module measures 4.54 x 10.75 inches, and it is designed to operate optimally within a temperature range of 0 to 50 °C and can be stored in temperatures ranging from –55 to 150 °C. The module’s performance remains stable in environments with relative humidity levels of 5% to 90%, ensuring reliability in various conditions.

Attribute Description
Part Number 776572-04
Product Name National Instruments SCXI-1104 Voltage Input Module
Signal Conditioning For medium-voltage signals
Voltage Input 30 VACrms, ±42 VACpeak, ±60 VDC
Filter Three-pole lowpass with a 2 Hz cutoff frequency
SCXIbus Interface Links the back signal connector to SCXIbus
Indirect Scanning Supported via switch on module
Connectivity Devices (required) SCXI-1310, TBX-96, BNC-2095, or SCXI-1300
Software Compatibility VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW
Device Driver NI-DAQ for Macintosh or PC Compatibles
Physical Dimensions 4.54 x 10.75 inches
Operating Temperature Range 0 to 50 °C
Storage Temperature Range –55 to 150 °C
Relative Humidity 5% to 90

Q1: What types of scanning does the National Instruments SCXI-1104 Voltage Input Module support, and which software platforms is it compatible with?
A1: The National Instruments SCXI-1104 Voltage Input Module is compatible with software platforms such as VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW, and it offers signal conditioning for medium-voltage signals with a capacity to handle 30 VACrms, ±42 VACpeak, and ±60 VDC voltage inputs.

Q2: Which software platforms are compatible with the National Instruments SCXI-1104 Voltage Input Module, and what range of signal conditioning does it offer?
A2: For successful integration with the National Instruments SCXI-1104 Voltage Input Module, connectivity devices such as the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 are required, and it is compatible with software platforms including VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW.

Q3: What types of connectivity devices are required for successful integration with the National Instruments SCXI-1104 Voltage Input Module?
A3: The National Instruments SCXI-1104 Voltage Input Module can handle 30 VACrms, ±42 VACpeak, and ±60 VDC voltage inputs and features a three-pole lowpass filter with a 2 Hz cutoff frequency; it requires connectivity devices like the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 for integration and is compatible with software platforms such as VirtualBench, ComponentWorks, Measure, LabWindows/C

Q4: What are the voltage handling capabilities and filter specifications of the National Instruments SCXI-1104 Voltage Input Module, and which connectivity devices and software platforms is it compatible with?
A4: For successful integration with the National Instruments SCXI-1104 Voltage Input Module, connectivity devices such as the SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 are required.

Q5: What connectivity devices are required for successful integration with the National Instruments SCXI-1104 Voltage Input Module, and which software platforms is it compatible with?
A5: The National Instruments SCXI-1104 Voltage Input Module supports indirect scanning and is compatible with various software platforms including VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW.