img

SCXI-1128

The National Instruments SCXI-1128 (Part Number: 776572-28) is a Matrix/Multiplexer Switch Module with a maximum switching power of 9 W per channel, a DC path resistance of less than 1.2 k

In Stock | Ships Today

img

    Description

    The National Instruments SCXI-1128, with its part number 776572-28, is a versatile Matrix/Multiplexer Switch Module that offers a maximum switching power of 9 W per channel and a maximum switching current of 30 mA per channel. It boasts a low DC path resistance of less than 1.2 kΩ, ensuring efficient signal transmission.

    Designed for swift operation, it has a relay operation time of typically 0.25 ms and an even quicker release time of typically 0.08 ms. With an impressive maximum scan rate of 1200 channels per second, it can swiftly cycle through connections, making it ideal for fast-paced testing environments. The module has a recommended warm-up time of 5 minutes before reaching optimal performance levels.

    Compatible with NI-SWITCH, LabVIEW, and Measurement Studio, this switch module integrates seamlessly into a range of software environments for ease of use and flexibility in application development. The physical dimensions of the module are 7.8 x 1.2 x 6.8 inches, and it has a light weight of just 6 ounces, making it compact and easy to install in various setups.

    With an operating temperature range from 0 °C to 50 °C and a storage temperature range from –20 °C to 70 °C, the SCXI-1128 is built to perform reliably under a wide range of conditions. Additionally, it can operate within a relative humidity range of 5% to 85% without condensation, which helps to prevent damage to the device and ensure longevity.

    Specification Value
    Part Number 776572-28
    Type Matrix/Multiplexer Switch Module
    Maximum Switching Power 9 W per channel
    Maximum Switching Current 30 mA per channel
    DC Path Resistance <1.2 kΩ
    Relay Operation Time 0.25 ms typical
    Release Time 0.08 ms typical
    Maximum Scan Rate 1200 channels/s
    Warm-Up Time 5 minutes recommended
    Software Compatibility NI-SWITCH, LabVIEW, Measurement Studio
    Physical Dimensions 7.8 x 1.2 x 6.8 in.
    Weight 6 oz
    Operating Temperature Range 0 °C to 50 °C
    Storage Temperature Range –20 °C to 70 °C
    Relative Humidity 5% to 85% (non-condensing)

    Question 1: What is the warm-up time recommended for the National Instruments SCXI-1128 to reach optimal performance levels?
    Answer 1: The DC path resistance of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module is less than 1.2 kΩ, which enhances its signal transmission efficiency by minimizing resistance and thereby reducing signal loss and voltage drops across the switch.

    Question 2: What is the maximum scan rate of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module, and what are the typical relay operation and release times?
    Answer 2: The National Instruments SCXI-1128 Matrix/Multiplexer Switch Module, part number 776572-28, features a maximum switching power of 9 W per channel and a maximum switching current of 30 mA per channel, with a low DC path resistance of less than 1.2 kΩ. It has a relay operation time of 0.25 ms, a release time of 0.08 ms, and a maximum scan rate of 1200 channels per second. It

    Question 3: What is the DC path resistance of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module, and how does this specification enhance its signal transmission efficiency?
    Answer 3: The National Instruments SCXI-1128 Matrix/Multiplexer Switch Module has a relay operation time of typically 0.25 milliseconds and an even quicker release time of typically 0.08 milliseconds, which allows for rapid cycling through connections, thus making it highly suitable for fast-paced testing environments where swift operation is critical.

    Question 4: What is the relay operation and release time of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module, and how does this affect its performance in fast-paced testing environments?
    Answer 4: The maximum scan rate of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module is 1200 channels per second, with typical relay operation and release times of 0.25 milliseconds and 0.08 milliseconds, respectively.

    Question 5: What are the key features and specifications of the National Instruments SCXI-1128 Matrix/Multiplexer Switch Module with part number 776572-28, including its switching capabilities, relay operation times, and environmental tolerances?
    Answer 5: The recommended warm-up time for the National Instruments SCXI-1128 to reach optimal performance levels is 5 minutes.