img

SCXI-1181

The SCXI-1181 Breadboard Custom Circuitry Module by National Instruments, with part number 776572-81, is designed for building custom simple, computerized, and timing circuits, providing a maximum regulated output voltage of +15 V,

In Stock | Ships Today

img

    Description

    The SCXI-1181 Breadboard Custom Circuitry Module, with Part Number 776572-81, is manufactured by National Instruments and is designed for applications involving custom simple, computerized, and timing circuits. This module is capable of providing a maximum regulated output voltage (V+) of +15 V, with a line regulation of 0.02%/V typical and a load regulation of 0.3% typical, while supporting a maximum current output of 170 mA.

    To ensure safety, the module requires 250 mA quick-acting fuses for protection against faults. It is compatible with various software packages, including NIDAQ, LabVIEW, LabWindows/CVI, and Borland C++, facilitating versatile applications in signal conditioning circuitry. The SCXI-1181 module features multiple connectors such as a 96-pin DIN C-type front connector, a 50-pin right-angle male strip back-signal connector, and a SCXIbus connector, providing robust connectivity options for users.

    Despite its obsolete status announced by National Instruments, the SCXI-1181 module remains available for purchase and repairs through Apex Waves, ensuring continued support for existing setups.

    Specification Details
    Part Number 776572-81
    Product Name SCXI-1181 Breadboard Custom Circuitry Module
    Manufacturer National Instruments
    Application Custom simple, computerized, and timing circuits
    Maximum Regulated Output Voltage (V+) +15 V
    Line Regulation 0.02%/V typical
    Load Regulation 0.3% typical
    Maximum Current Output 170 mA
    Fuse Requirement 250 mA quick-acting fuses
    Software Compatibility NIDAQ, LabVIEW, LabWindows/CVI, Borland C++
    Connectors
    • 96-pin DIN C-type front connector
    • 50-pin right-angle male strip back-signal connector
    • SCXIbus connector
    Obsolete Status Announced by National Instruments, available for purchase and repairs by Apex Waves

    Question 1: What are the key features and compatibility options of the National Instruments SCXI-1181 Breadboard Custom Circuitry Module, and how does its obsolete status affect its availability for purchase and repairs?
    Answer 1: The SCXI-1181 Breadboard Custom Circuitry Module manufactured by National Instruments offers a maximum regulated output voltage (V+) of +15 V, line regulation of 0.02%/V typical, load regulation of 0.3% typical, and a maximum current output of 170 mA. It includes connectivity options such as a 96-pin DIN C-type front connector, a 50-pin right-angle male strip back-signal connector, and an SCXIbus connector for various connectivity requirements

    Question 2: What are the specifications and connectivity options for the SCXI-1181 Breadboard Custom Circuitry Module manufactured by National Instruments?
    Answer 2: The SCXI-1181 Breadboard Custom Circuitry Module by National Instruments has a maximum regulated output voltage of +15 V, line regulation of 0.02%/V typical, load regulation of 0.3% typical, and supports a maximum current output of 170 mA; it features 250 mA quick-acting fuses for protection, and offers software compatibility with NIDAQ, LabVIEW, LabWindows/CVI, and Borland C++, including a 96-pin DIN C

    Question 3: What are the key specifications and compatibility features of the SCXI-1181 Breadboard Custom Circuitry Module manufactured by National Instruments?
    Answer 3: The SCXI-1181 Breadboard Custom Circuitry Module offers connectivity options including a 96-pin DIN C-type front connector, a 50-pin right-angle male strip back-signal connector, and an SCXIbus connector, and support and repairs can be obtained through Apex Waves despite its obsolete status.

    Question 4: What is the purpose of the 250 mA quick-acting fuses in the SCXI-1181 Breadboard Custom Circuitry Module manufactured by National Instruments?
    Answer 4: The 250 mA quick-acting fuses in the SCXI-1181 Breadboard Custom Circuitry Module are designed to provide protection against faults, ensuring the safety of the module during operation.

    Question 5: What are the connectivity options available on the SCXI-1181 Breadboard Custom Circuitry Module, and through which company can support and repairs be obtained despite its obsolete status?
    Answer 5: The National Instruments SCXI-1181 Breadboard Custom Circuitry Module offers key features such as a maximum regulated output voltage of +15 V, line and load regulation of 0.02%/V typical and 0.3% typical respectively, and a maximum current output of 170 mA, along with safety measures like 250 mA quick-acting fuses. It is compatible with software packages including NIDAQ, LabVIEW, LabWindows/CVI, and Borland C++, and provides