Description
The SCXI-1308 is a 32-Channel Terminal Block with a part number of 777687-08 designed for compatibility with SCXI-1102/B/C and SCXI-1100 modules. It features 32 precision resistors each valued at 249 Ω to effectively measure current ranges from 0 to 20 mA and 4 to 20 mA, translating to a voltage measurement range of 0.996 to 4.98 VDC for the latter. The terminal block is engineered to handle channel-to-channel voltages up to 30 Vrms and channel-to-earth voltages of 42.4 Vpeak or 60 VDC.
Operational efficiency is maintained within an operating temperature range of 0° to 50° C and a storage temperature range from –20° to 70° C. The device also boasts a relative humidity range of 5% to 90% (non-condensing), ensuring reliability under various environmental conditions. Despite its obsolete status announced by National Instruments, the SCXI-1308 remains available for purchase and repair through Apex Waves. Ensuring accurate performance, calibration services are available and are recommended annually or biennially to maintain the device’s precision.
Feature | Specification |
---|---|
Part Number | SCXI-1308 |
NI Part Number | 777687-08 |
Type | 32-Channel Terminal Block |
Compatible Modules | SCXI-1102/B/C, SCXI-1100 |
Resistor Value | 249 Ω |
Current Measurement Range | 0 to 20 mA, 4 to 20 mA |
Voltage Measurement Range for 4 to 20 mA | 0.996 to 4.98 VDC |
Channel-to-Channel Voltage | Up to 30 Vrms |
Channel-to-Earth Voltage | 42.4 Vpeak or 60 VDC |
Operating Temperature Range | 0° to 50° C |
Storage Temperature Range | –20° to 70° C |
Relative Humidity Range | 5% to 90% (non-condensing) |
Obsolete Status | Announced by National Instruments, available from Apex Waves |
Calibration | Available; recommended annually or biennially |
Question 1: Considering the SCXI-1308’s specifications and operating conditions, what are the recommended intervals for calibration services to maintain its accuracy?
Answer 1: The recommended calibration intervals for the SCXI-1308 32-Channel Terminal Block to maintain accurate performance are annually or biennially.
Question 2: Considering its operational specifications and environmental tolerance, what are the recommended calibration intervals for the SCXI-1308 32-Channel Terminal Block to maintain accurate performance?
Answer 2: The recommended intervals for calibration services to maintain the accuracy of the SCXI-1308 are annually or biennially.
Question 3: What are the key specifications and maintenance recommendations for the SCXI-1308, a 32-Channel Terminal Block with a part number of 777687-08, and its compatibility with SCXI modules?
Answer 3: The SCXI-1308 32-Channel Terminal Block is capable of measuring voltage in the range of 0.996 to 4.98 VDC for the 4 to 20 mA current range and can operate within an ambient temperature range of 0° to 50° C, with a relative humidity range of 5% to 90% (non-condensing).
Question 4: What are the key specifications and compatibility details of the SCXI-1308 32-Channel Terminal Block, including its operational voltage and temperature ranges, and what services are offered by Apex Waves for this device despite its obsolete status?
Answer 4: The SCXI-1308, part number 777687-08, is a 32-Channel Terminal Block compatible with SCXI-1102/B/C and SCXI-1100 modules, featuring 32 resistors valued at 249 Ω for current measurements ranging from 0 to 20 mA and 4 to 20 mA, channel-to-channel voltages up to 30 Vrms, and channel-to-earth voltages of 42.4 Vpeak or 60 VDC
Question 5: What are the specific voltage measurement capabilities and environmental operating conditions for the SCXI-1308 32-Channel Terminal Block?
Answer 5: The SCXI-1308 is a 32-Channel Terminal Block compatible with SCXI-1102/B/C and SCXI-1100 modules, featuring 32 precision resistors valued at 249 Ω for current measurements ranging from 0 to 20 mA and 4 to 20 mA, translating to a voltage range of 0.996 to 4.98 VDC, with operational channel-to-channel voltages up to 30 Vrms and channel-to-earth voltages up