Description
Tektronix TDS3034B Digital Phosphor Oscilloscope
The Tektronix TDS3034B Digital Phosphor Oscilloscope has a state activation framework, helpful for taking care of computerized issues and synchronous state logic machines, which triggers if a state signal is true or false right when a clock signal transition is valid. This model offers pulse trigger functions that activate the oscilloscope when a signal meets a time or limit condition.
This oscilloscope also includes a Press Width (or Glitch). The Pulse Width triggers the oscilloscope when a signal pulse width is less than, more prominent than, equivalent to, or not equivalent to a predetermined pulse width. The pulse width trigger is valuable for advanced logic troubleshooting. The TDS3034B has a Runt Pulse that triggers the oscilloscope when a signal pulse is less than a predetermined edge level. The user can likewise indicate runt pulse width parameters; this trigger is helpful for bus-contention issues.
This model has a Slew Rate that triggers the oscilloscope when a signal's slew rate (rise or fall time) is less than, more prominent than, equivalent to, or not equivalent to a slew rate. This trigger is valuable for investigating advanced bus transceivers, transmission lines, and operation amp circuits.
The TDS3034B Digital Phosphor Oscilloscope offers quick and straightforward verification that the circuit is working inside its proposed parameters. This is perfect for redundant testing applications where quick Go/No-Go choices are required. The user can make waveform reference formats to contrast with their live waveforms. The user can also likewise contrast any number of information channels and any blend of four references, and select activities for the TDS3034B oscilloscope to take if a waveform strays outside as far as possible: stop acquisition, sound a beep, print a copy, or save the waveform to disk.
Technical Specifications
TDS3034B | Technical Specifications & Electrical Characteristics |
---|---|
Bandwidth | 300 MHz |
Channels | 4 |
Sample Rate on Each Channel | 2.5 GS/s |
Maximum Record Length | 10 K points |
Vertical Resolution | 9 Bits |
Vertical Sensitivity (/div) | 1 mV to 10 V |
Vertical Accuracy | ±2% |
Max Input Voltage (1 M ohms) | 150 VRMS CAT I (300 V CAT II with standard 10X probe) |
Position Range | ±5 div |
BW Limit | 20, 150 MHz |
Input Coupling | AC, DC, GND |
Input Impedance Selections | 1 M ohms in parallel with 13 pF or 50 ohms |
Time Base Range | 2 ns to 10 s/div |
Time Base Accuracy | 20 ppm |
Display Monitor (VGA) | Color active matrix LCD |
Physical Dimensions | Inches |
Width | 15 |
Height | 7 |
Depth | 6 |
Weight | 7 lbs without battery |
Weight | 11 lbs with battery |