TDS3054B

Digital Phosphor Oscilloscope with 4 channels

Categories: ,

In Stock | Ships Today

img

    Description

    Tektronix TDS3054B Digital Phosphor Oscilloscope

    The TDS3054B Digital Phosphor Oscilloscope highlights the insights about the history of a signal's movement, making it less demanding to comprehend the attributes of the waveforms the user has captured. An expansion in execution from 500 to 600 MHz data transfer capacity offers a 20% change in rise-time estimation exactness, as delineated with these estimations of a 20 ps rising edge. The lower trace is a reference waveform, demonstrating the rise-time execution of a 500 MHz oscilloscope. The upper trace demonstrates the improved execution of a 600 MHz oscilloscope.

    The TDS3054B's 5 GS/s continuous sample rate and sin(x)/x interpolation guarantee exact reproduction of a 500 MHz of a sine wave. Indeed, even with 2 GS/s sample rate, which surpasses the Nyquist prerequisite of 2X oversampling, this 500 MHz oscilloscope with direct addition does not give precise reconstruction of a similar 500 MHz sine wave. The user can also search for accidental circuit noise with the TDS3054B FFT capacity.

    The TDS3054B DPO with the TDS3LIM testing module is perfect for assembling test applications where quick Go/No-Go choices are required. This model also has a Peak Detect, with high recurrence and arbitrary glitch catch which catches glitches as restricted as 1 ns.

    This model has a bandwidth of 500 MHz, a 20,150 MHz BW Limit, 1 ns to 10 s/div Time Base Ranger, and 5 GS/s Sample Rate on Each Channel.

    If you are interested in this model and you want to learn more about its specifications and options, you can check out its manual on the ApexWaves.com website.

     

    Technical Specifications


    TDS3054B Technical Specifications & Electrical Characteristics
    Bandwidth 500 MHz
    Channels 4
    Sample rate on each channel 5 GS/s
    Maximum record length 10 K points on all models
    Vertical resolution 9 Bits on all models
    Vertical sensitivity 1 mV – 10 V on all models
    Vertical accuracy ±2% on all models
    Max input voltage (1 MΩ) 150 VRMS CAT I on all models (300 V CAT II with standard 10X probe)
    Position range ± 5 div on all models
    BW limit 20, 150 MHz
    Input coupling AC, DC, GND on all models
    Input impedance selections 1 MΩ in parallel with 13 pF or 50 Ω on all models
    Time base Range 1 ns – 10 s/div
    Time base Accuracy 20 ppm on all models
    Display (VGA) Color active matrix LCD on all models